Feature

New on Version 9

Plain comparison. Results from several signals are tabulated without additional arithmetic or statistical calculations

New

Reverse baseline subtraction. An option can be activated in the parameter file that will instruct the software to hold off the processing of a sample until a blank is acquired. This is useful for high temperature simulated distillation where it is preferable to use the blank after the sample and not the one prior.

New

Graphical adjustment of quenching window. Two markers that indicate the beginning and end of the solvent peak can be moved with the mouse.

New

Automatic quenching window detection. When this option is activated in the parameter data file, an algorithm is used to try to detect the beginning and end of the solvent peak.

New

Define different marketing versions:

-       Lite

1.     No report comparison

2.     Only 1 cut point table

3.     No blending

4.     No e-mail

5.     No DHA optimization

6.     No custom tables or formulas

7.     No custom validation conditions

-       Advance: All the features are enabled but only one type of detector is allowed.

-       Multi-channel: like Advance but allows signals from multiple detectors (i.e. Sulfur, Nitrogen, etc.)

-       MS: all the features available in the Advance version plus a module to carry out saturate and aromatic analysis by MS.

New

Y axis was added to the retention time signal.

New

Allows to select which components can be reported as gases in the ASTM D-7096

New

The sample name is now included when exporting a comparison table

New

The print routine was modified to create a single job when printing several reports. This is useful when printing to  PDF. Instead of creating a document for each selected result within a signal, only one file will be created.

New

Calculated Flash Point as per ASTM-D7215

New

More features were added to the formula editor

1.     Calculated Flash Point D56

2.     Calculated Flash Point D93

3.     Calculated Flash Point D3828

4.     Calculated D86

5.     Calculated D1160

New

IBP and FBP markers can be shown with the signal.

New

Button to select and unselect all skewness marks in the component table

New

A column that shows the %deviation from the theoretical response factor was added in the calibration reports for ASTM-D7096.

New

BP data can be imported from the clipboard into the DHA optimization table.

New

When an MCR is loaded, the original signal file name is shown in the toggle buttons. The previous versions showed the MCR file name.

New

Automatic blank selection when loading signal files. An option is available to allow the software chose the blank signal that was acquired closest to the sample signal.

New

Results tables can be copy to clipboard and then paste it into other applications such as MS Excel.

New

An option to skip solvent peak during external standard calibration was added in the integration page of the parameter file.

New

Button to select / deselect all signals was added to the print and export dialogs.

New

A button to select target folder was added in the export page of the parameter data file.

New

QC tables can be saved directly from within the Boiling Point table. This avoids the use of third party applications such as Notepad.

New

Location of parameter and system files can be configured from within the application. This avoids the use of third party applications such as Notepad

New

Method ASTM-D7398 was added.

New

User-define validation conditions were added to the parameter data file. Example, trigger warning if BP[90] > 350C.

New

The extension of the ASCII files can be defined by the user within the parameter file.

New

Redesigned graphic editor for page’s header and footer.

New

Allows the selection of the model for volume conversion for crude methods: Polynomial model or proposed ASTM XXXX

New

Additional simulated distillation methods were added:

·         ASTM-D7398

·         ASTM-D7500

·         ASTM-D5399

 

New

All the simulated distillation methods are supported in one application. The ASTM and non-ASTM methods available are:

·         ASTM D-2887 (low, extended and high temperature)

·         ASTM D-3710

·         ASTM D-5307 (low, extended and high temperature)

·         LUBE (low, extended and high temperature)

·         Crude by External Standard (low, extended and high temperature)

 

Support of additional calculations:

·         User defined cut points

·         Optimizable D-86 & D-1160 correlations (D-2887 & D-3710)

·         Liquid / Vapor ratio (D-3710)

·         Reid Vapor Pressure (D-3710)

·         Gases (D-3710)

·         Motor Oil Volatility (LUBE)

·         Recovery (All methods except D-3710)

 

On-screen peak identification. This feature allows the user to visually verify and correct time calibration. The retention time chromatogram is displayed on the screen with components' name on the apex of each identified peak. No typing is required to make corrections.

 

On-screen sample analysis. Sample chromatograms, calculations and plots are displayed on the screen.

 

Customizable printed reports.

 

Users and access levels can be defined for security purpose.

 

Multiple stored reports can be compared, both on screen and on paper, against the sample being analyzed.

 

Several chromatograms can be overlaid in the analysis mode.

 

Automatic update of all the calculations and plots when the start or end of elution mark is changed on screen.

 

Automatic adjustment of the elution detection algorithms. While in the on-screen sample analysis mode, the software can be instructed to learn the user defined elution marks.

 

Blank chromatogram can be changed or removed while analyzing a sample.

 

Customizable boiling point table. Any percent off can be added or removed from the table.

 

Customizable resolution points.

 

Expanded integration parameters:

·         New baseline algorithm. This option enhances the shape of the blank signal before is subtracted from the sample chromatogram.

·         A new algorithm for samples with slow elution can be used instead of the ASTM procedure.

·         End of sample can be set based on the retention time of the last carbon in the calibration.

·         The option to zero the signal or shift the chromatogram can be defined for negative slices.

 

User-defined correlation points can be added and optimized.

 

Carbon numbers can be used to define cut points.

 

Carbon number versus percent off can be plotted.

 

Volume calculations for crude samples.

 

Customizable ASCII reports.

 

Customizable color layout.

 

Multi-language (English and Spanish)

 

Multi-Channel ready. Different types of signals can be handled on the same session:

·         Carbon

·         Sulfur

·         Nitrogen

·         Hydrogen

·         Etc.

 

Sample blending simulation.

 

Boiling point correction by Detailed Hydrocarbon Analysis.

 

Calculation of average and percent standard deviation during report comparison.

 

Multiple cut point tables.

 

Cut points can be labeled.

 

Graphic view of cut point tables: Bar and Line charts.

 

Views can be sent to Clipboard or Windows Enhanced Metafiles.

 

Baseline signal can be viewed with sample signal.

 

ASCII reports can be sent to another application.

 

Special application can be executed automatically on QC failure.

 

Results can be exported to MS Excel (requires MS Excel)

 

Average and standard deviation can be calculated when comparing results.

 

Ratios can be used when comparing results.

 

Built-in peak integrator.

 

Interactive distillation. Displays the percent distilled and temperature in any point of the signal chromatogram.

 

Noack volatility calculation by DIN51581-2

 

Measures skewness of multiple peaks

 

Measures response factors of multiple components

 

New ASTM D7096

 

Cetane Index by ASTM D-976

 

Cetane Index by ASTM D-4737

 

Calculated Flash Point

 

More options in the formula editor

 

The report comparison can be exported to ASCII or Excel

 

Distillation chart that shows temperature and time in the X axis.

 

Built-in e-mail system does not require third-party program such as MS Outlook

 
   

 

 